Analytical HPLC System LAHS-B11 is a unit equipped with LCD display UV-Visible wavelength range of 190 nm to 700 nm and double plunger reciprocating pump system for constant flow pump. It has gradient kit system for test result accuracy. Consists of separate workstation, sample injector and front mounted self-locking switch. Deuterium lamp is used as light source with valve mounting frame. It is ideally used in the detection of compounds in pharmaceutical industries, research institute, food industries, and petroleum industries, etc.

High Pressure Constant Flow Pump <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Double plunger reciprocating pump</strong></td><td>2 sets</td></tr><tr><td><strong>Flow range</strong></td><td>0.001 to 10.00 mL/min</td></tr><tr><td><strong>Setting step size</strong></td><td>0.001 mL/min</td></tr><tr><td><strong>Flow accuracy</strong></td><td>≤ ± 0.3 %</td></tr><tr><td><strong>Flow stability</strong></td><td>RSD ≤ 00.1 %</td></tr><tr><td><strong>Maximum pressure</strong></td><td>42 MPa</td></tr><tr><td><strong>Display pressure error</strong></td><td>≤ 1.0 %</td></tr><tr><td><strong>Pressure fluctuation</strong></td><td>≤ 1.0 %</td></tr><tr><td><strong>Power consumption</strong></td><td>80 W</td></tr></table>
UV/Visible Detector <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Wavelength range</strong></td><td>190 to 700 nm</td></tr><tr><td><strong>Wavelength repeatability</strong></td><td>± 0.1 nm</td></tr><tr><td><strong>Band width</strong></td><td>8 nm</td></tr><tr><td><strong>Response time</strong></td><td>0 to 4.9 seconds</td></tr><tr><td><strong>Linearity range</strong></td><td>1.8 AU (5 %)</td></tr><tr><td><strong>Baseline Noise</strong></td><td>≤ ± 1 × 10<sup>-5</sup>AU</td></tr><tr><td><strong>Baseline drift</strong></td><td>≤ 2.0 × 10<sup>-4</sup>AU/h</td></tr><tr><td><strong>Minimum detectable concentration</strong></td><td>4.0 × 10<sup>-9</sup> g/mL</td></tr><tr><td><strong>Detector cell</strong></td><td>Optical path: 10 mm<hr> Volume: 10 µL</td></tr><tr><td><strong>Light source</strong></td><td>Deuterium lamp</td></tr><tr><td><strong>Power consumption</strong></td><td>100 W</td></tr><tr><td><strong>Voltage</strong></td><td>AC 110 V/ 220 V ± 10 %, 50/60 Hz</td></tr><tr><td><strong>Packing Dimensions (W × D × H)</strong></td><td>600 × 440 × 380 mm<hr> 3 × (600 × 410 × 300 mm</td></tr><tr><td><strong>Gross weight</strong></td><td>75 kg</td></tr></table>
  • Double plunger reciprocating pump system
  • Gradient system kits
  • Sample injector: 1 set
  • Deuterium lamp light source
  • Separate workstation
  • LCD display for value observation
  • Front mounted self-locking switch
  • Output: USB port
  • Compact and easy to install
Widely used in pharmaceutical, petroleum, research institute, food industrial applications in separation and detection of mixture of compounds in chemical analysis, poison analysis, environmental analysis, protein food detection, medicine testing, and polymer analysis.

Analytical HPLC

Analytical HPLC-A7835

Analytical HPLC-A7835

  • Pump Specifications
  • Model NoHPP-B1Flow rate range0.0001 to 10 ml / minMaximum pressure42 MPa , 0 to 5 ml / minColumn size4.6 × 250 mmSample size5 μmPressure pulsation≤ 1.5 % at 10 MPaFlow rate accuracy± 0.2 % at 1 ml / minFlow rate repeatability %≤ 0.15Gradient accuracy %± 2Gradient repeatability %≤ 0.2Dimension450 × 260 × 190 mmPower supply90 V to 240 VWeight11.2 kg
  • Detector Specifications
  • Model NoHPD-B2Wavelength range190 to 800 nmWavelength accuracy± 0.75 nmWavelength repeatability0.2 nmBand width8 nmOptical path10 nmDeuterium lamp190 to 400 nmTungsten lamp400 to 800 nmBaseline noise ( Static ) Au≤ ± 0.5 × 10 -5Baseline drift ( Static ) Au / h≤ 1.5 x 10 -4Minimum detection limit≤ 4 x 10 -8Power100 WPower supply90 V / 50 to 60 HzDimension460 × 260 × 190 mmWeight9.2 kg
Analytical HPLC System LAHS-B10

Analytical HPLC System LAHS-B10

  • High Pressure Constant Flow Pump
  • Double plunger reciprocating pump1 setFlow range0.001 to 10.00 mL/minSetting step size0.001 mL/minFlow accuracy≤ ± 0.3 %Flow stabilityRSD ≤ 00.1 %Maximum pressure42 MPaDisplay pressure error≤ 1.0 %Pressure fluctuation≤ 1.0 %Power consumption80 W
  • UV/Visible Detector
  • Wavelength range190 to 700 nmWavelength repeatability± 0.1 nmBand width8 nmResponse time0 to 4.9 secondsLinearity range1.8 AU (5 %)Baseline Noise≤ ± 1 × 10-5AUBaseline drift≤ 2.0 × 10-4AU/hMinimum detectable concentration4.0 × 10-9 g/mLDetector cellOptical path: 10 mm Volume: 10 µLLight sourceDeuterium lampPower consumption100 WVoltageAC 110 V/ 220 V ± 10 %, 50/60 HzPacking Dimensions (W × D × H)600 × 440 × 380 mm 2 × (600 × 410 × 300 mmGross weight54 kg
Analytical HPLC System LAHS-A10

Analytical HPLC System LAHS-A10

  • Pump specification
  • TypeQuaternary Low Pressure PumpFlow Rate Range0.001 to 10.000 ml/min, in 0.001ml incrementsFlow Accuracy≤ ± 0.2% (1.00 ml/min, H2 O, R.T., 8.5 MPa)Flow PrecisionRSD ≤ 0.06% (1.00 ml/min, H2 O, R.T., 8.5MPa)Maximum Pressure63 MPaPressure accuracy≤ ± 3.0 %Pressure pulsation≤ 0.1 MPaComposition rang0 to 100 %Composition precision≤ 0.3 % RSD
  • UV/VIS Detector
  • Wavelength Range190 to 800 nmWavelength Repeatability≤ 0.1 nmWavelength Accuracy≤ ± 1.0 nmBand Width6 nmResponse Time0.0 s to 5 sBaseline Noise≤ ± 0.25 × 10-5 AU(empty cell, 254 nm, 1.0s)Drift≤ 0.5 × 10-4 AU/h (empty cell, 254 nm, 60 min)Path length10 mm(analytical cell)Light SourceDeuterium Lamp and Tungsten Lamp
  • Data-processing Workstation
  • System contain the tables for regular samples Equipped with Internal and external standard calculation process Automatic display, print, export of data and starting of another program on completion on measurement Observe with the condition of 21 CFR part 11 directive of the FDA
Analytical HPLC-A7832

Analytical HPLC-A7832

  • Detector Specifications
  • Model No HPD-A20 HPD-A21 Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm ) Wavelength accuracy ± 0.5 nm ± 2 nm Wavelength repeatability 0.15 nm 0.3 nm Band width 8 nm 8 nm Optical path 10 nm 10 nm Deuterium lamp 190 to 400 nm 190 to 400 nm Tungsten lamp 400 to 800 nm 400 to 800 nm Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5 Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4 Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8 Power 100 W 100 W Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm Weight 9.5 kg 9.5 kg
  • Pump Specifications
  • Flow rate range0.0001 to 10 ml / minMaximum pressure50 MPa , 0 to 2 ml / minColumn size4.6 × 250 mmSample size5 µmPressure pulsation≤ 1 % at 10 MPaFlow rate accuracy± 0.15 % at 1 ml / minFlow rate repeatability %≤ 0.1Gradient accuracy %± 1.5Gradient repeatability %≤ 0.2Dimension460 × 310 × 180 mmPower supply90 VWeight11.6 kg

Standard HPLC

HPLC system LHLC-B11

HPLC system LHLC-B11

  • High pressure pump
  • High pressure constant-current infusion pump
  • Infusion Way
  • Micro volume series dual-piston
  • Infusion pressure
  • 0 - 9999 Psi
HPLC system LHLC-A11

HPLC system LHLC-A11

  • High pressure pump
  • Two sets of pump
  • Flow rate range
  • 0.001 - 9.999 mL / min (0.001 mL / min increments)
  • Pressure range
  • ≤ 0.5 MPa (0 - 42 MPa)
HPLC system LHLC-A10

HPLC system LHLC-A10

  • High pressure pump
  • Single pump
  • Flow rate range
  • 0.001 - 9.999 mL / min (0.001 mL / min increment)
  • Pressure range
  • ≤ 0.5 MPa (0 - 42 MPa)
HPLC system LHLC-B10

HPLC system LHLC-B10

  • High pressure pump
  • High pressure gradient pump
  • Peak operating pressure
  • 45 MPa, Stainless steel pump
  • Pressure
  • ± 0.02 MPa