Analytical HPLC System LAHS-A10 features Quaternary Low Pressure Pump with 0.001-10 ml/min pump flow rate. Incorporated UV-Vis detector with a range of 190 to 800 nm that examines sample absorption at different wavelengths and a high pressure pump providing continuous stable flow. This HPLC system offers high speed accuracy, resolving power, detection, quantification, convenience and applicability to new sample types. 

Pump specification <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Type</strong></td><td>Quaternary Low Pressure Pump</td></tr><tr><td><strong>Flow Rate Range</strong></td><td>0.001 to 10.000 ml/min, in 0.001ml increments</td></tr><tr><td><strong>Flow Accuracy</strong></td><td>≤ ± 0.2% (1.00 ml/min, H<sub>2 </sub>O, R.T., 8.5 MPa)</td></tr><tr><td><strong>Flow Precision</strong></td><td>RSD ≤ 0.06% (1.00 ml/min, H<sub>2 </sub>O, R.T., 8.5MPa)</td></tr><tr><td><strong>Maximum Pressure</strong></td><td>63 MPa</td></tr><tr><td><strong>Pressure accuracy</strong></td><td>≤ ± 3.0 %</td></tr><tr><td><strong>Pressure pulsation</strong></td><td>≤ 0.1 MPa</td></tr><tr><td><strong>Composition rang</strong></td><td>0 to 100 %</td></tr><tr><td><strong>Composition precision</strong></td><td>≤ 0.3 % RSD</td></tr></table>
UV/VIS Detector <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Wavelength Range</strong></td><td>190 to 800 nm</td></tr><tr><td><strong>Wavelength Repeatability</strong></td><td>≤ 0.1 nm</td></tr><tr><td><strong>Wavelength Accuracy</strong></td><td>≤ ± 1.0 nm</td></tr><tr><td><strong>Band Width</strong></td><td>6 nm</td></tr><tr><td><strong>Response Time</strong></td><td>0.0 s to 5 s</td></tr><tr><td><strong>Baseline Noise</strong></td><td>≤ ± 0.25 × 10<sup>-5 </sup> AU(empty cell, 254 nm, 1.0s)</td></tr><tr><td><strong>Drift</strong></td><td>≤ 0.5 × 10<sup>-4 </sup> AU/h (empty cell, 254 nm, 60 min)</td></tr><tr><td><strong>Path length</strong></td><td>10 mm(analytical cell)</td></tr><tr><td><strong>Light Source</strong></td><td>Deuterium Lamp and Tungsten Lamp</td></tr></table>
Data-processing Workstation System contain the tables for regular samples<br/> Equipped with Internal and external standard calculation process<br/> Automatic display, print, export of data and starting of another program on completion on measurement<br/> Observe with the condition of 21 CFR part 11 directive of the FDA
System Kits 1 Set<br/> Combined A/D converters<br/> Combined vacuum degasser and 4 channel
Power Supply AC 110 /220 V ±1 0 %, 50/60 Hz
Dimension 710 × 583× 500mm; 770 × 450 × 700 mm
Weight 156 kg
  • UV-Vis detector with a range of 190 to 800 nm
  • Consist of Quaternary Low Pressure Pump
  • Advance and intellectual HPLC system
  • Excellent Flow Accuracy and Pressure Accuracy
  • Column oven with greater capacity of 3 column with maximum thickness ID10 × 250 mm
  • Fast and stable UDP communication protocol, can be used for instrument remote control
  • Enhancement of up to 5 mm stroke of plunger rod with good performance and high pressure constant flow pump or parallel pump head
  • Complies with FDA 21 CFR part 11
High Performance Liquid Chromatography system has been widely used in Research and Development, pharmaceutical, food nutrient analysis of amino acids and sugars, detection of food contaminants, environmental pollutant and chemical product purity.

Analytical HPLC

Analytical HPLC-A7835

Analytical HPLC-A7835

  • Pump Specifications
  • Model NoHPP-B1Flow rate range0.0001 to 10 ml / minMaximum pressure42 MPa , 0 to 5 ml / minColumn size4.6 × 250 mmSample size5 μmPressure pulsation≤ 1.5 % at 10 MPaFlow rate accuracy± 0.2 % at 1 ml / minFlow rate repeatability %≤ 0.15Gradient accuracy %± 2Gradient repeatability %≤ 0.2Dimension450 × 260 × 190 mmPower supply90 V to 240 VWeight11.2 kg
  • Detector Specifications
  • Model NoHPD-B2Wavelength range190 to 800 nmWavelength accuracy± 0.75 nmWavelength repeatability0.2 nmBand width8 nmOptical path10 nmDeuterium lamp190 to 400 nmTungsten lamp400 to 800 nmBaseline noise ( Static ) Au≤ ± 0.5 × 10 -5Baseline drift ( Static ) Au / h≤ 1.5 x 10 -4Minimum detection limit≤ 4 x 10 -8Power100 WPower supply90 V / 50 to 60 HzDimension460 × 260 × 190 mmWeight9.2 kg
Analytical HPLC System LAHS-B10

Analytical HPLC System LAHS-B10

  • High Pressure Constant Flow Pump
  • Double plunger reciprocating pump1 setFlow range0.001 to 10.00 mL/minSetting step size0.001 mL/minFlow accuracy≤ ± 0.3 %Flow stabilityRSD ≤ 00.1 %Maximum pressure42 MPaDisplay pressure error≤ 1.0 %Pressure fluctuation≤ 1.0 %Power consumption80 W
  • UV/Visible Detector
  • Wavelength range190 to 700 nmWavelength repeatability± 0.1 nmBand width8 nmResponse time0 to 4.9 secondsLinearity range1.8 AU (5 %)Baseline Noise≤ ± 1 × 10-5AUBaseline drift≤ 2.0 × 10-4AU/hMinimum detectable concentration4.0 × 10-9 g/mLDetector cellOptical path: 10 mm Volume: 10 µLLight sourceDeuterium lampPower consumption100 WVoltageAC 110 V/ 220 V ± 10 %, 50/60 HzPacking Dimensions (W × D × H)600 × 440 × 380 mm 2 × (600 × 410 × 300 mmGross weight54 kg
Analytical HPLC System LAHS-B11

Analytical HPLC System LAHS-B11

  • High Pressure Constant Flow Pump
  • Double plunger reciprocating pump2 setsFlow range0.001 to 10.00 mL/minSetting step size0.001 mL/minFlow accuracy≤ ± 0.3 %Flow stabilityRSD ≤ 00.1 %Maximum pressure42 MPaDisplay pressure error≤ 1.0 %Pressure fluctuation≤ 1.0 %Power consumption80 W
  • UV/Visible Detector
  • Wavelength range190 to 700 nmWavelength repeatability± 0.1 nmBand width8 nmResponse time0 to 4.9 secondsLinearity range1.8 AU (5 %)Baseline Noise≤ ± 1 × 10-5AUBaseline drift≤ 2.0 × 10-4AU/hMinimum detectable concentration4.0 × 10-9 g/mLDetector cellOptical path: 10 mm Volume: 10 µLLight sourceDeuterium lampPower consumption100 WVoltageAC 110 V/ 220 V ± 10 %, 50/60 HzPacking Dimensions (W × D × H)600 × 440 × 380 mm 3 × (600 × 410 × 300 mmGross weight75 kg
Analytical HPLC-A7832

Analytical HPLC-A7832

  • Detector Specifications
  • Model No HPD-A20 HPD-A21 Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm ) Wavelength accuracy ± 0.5 nm ± 2 nm Wavelength repeatability 0.15 nm 0.3 nm Band width 8 nm 8 nm Optical path 10 nm 10 nm Deuterium lamp 190 to 400 nm 190 to 400 nm Tungsten lamp 400 to 800 nm 400 to 800 nm Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5 Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4 Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8 Power 100 W 100 W Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm Weight 9.5 kg 9.5 kg
  • Pump Specifications
  • Flow rate range0.0001 to 10 ml / minMaximum pressure50 MPa , 0 to 2 ml / minColumn size4.6 × 250 mmSample size5 µmPressure pulsation≤ 1 % at 10 MPaFlow rate accuracy± 0.15 % at 1 ml / minFlow rate repeatability %≤ 0.1Gradient accuracy %± 1.5Gradient repeatability %≤ 0.2Dimension460 × 310 × 180 mmPower supply90 VWeight11.6 kg

Standard HPLC

HPLC system LHLC-B10

HPLC system LHLC-B10

  • High pressure pump
  • High pressure gradient pump
  • Peak operating pressure
  • 45 MPa, Stainless steel pump
  • Pressure
  • ± 0.02 MPa
HPLC system LHLC-B11

HPLC system LHLC-B11

  • High pressure pump
  • High pressure constant-current infusion pump
  • Infusion Way
  • Micro volume series dual-piston
  • Infusion pressure
  • 0 - 9999 Psi
HPLC system LHLC-A10

HPLC system LHLC-A10

  • High pressure pump
  • Single pump
  • Flow rate range
  • 0.001 - 9.999 mL / min (0.001 mL / min increment)
  • Pressure range
  • ≤ 0.5 MPa (0 - 42 MPa)
HPLC system LHLC-A11

HPLC system LHLC-A11

  • High pressure pump
  • Two sets of pump
  • Flow rate range
  • 0.001 - 9.999 mL / min (0.001 mL / min increments)
  • Pressure range
  • ≤ 0.5 MPa (0 - 42 MPa)