Online ozone meter LOOM-A10 is based on advanced microprocessor technology. It monitors the changes of ozone concentration in the air and can automatically change the ozone measurement ranges. The UV absorption for monitoring low concentration of ozone is based on Beer-Lambert law. Features like real-time monitoring, auto zero calibration and built-in printer makes this unit suitable for most atmospheric monitoring requirements.

Ozone measurement range0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional )
Flow rate1.5 L/min
Accuracy0.01 ppm or 3 % of reading
Resolution0.001 ppm
Sampling Time10 seconds
Boot time≥ 30
Operating temperature10 °C ∼ 40 °C
Operational humidity10 % ∼ 90 % RH
Gas pipe diameterØ 4 mm
Output mode4 ∼ 20 mA, 0 ∼ 5 V DC; Modbus 485
Power24 VDC ± 10 %
Dimensions150 x 90 x 325 mm
Weight1.9 kgs
  • Measuring mode : Automatic
  • Ozone Detection using the UV absorption
  • Auto zero calibration for precise results
  • Good anti-jamming performance
  • High measurement performance with fast response
  • Good stability and reproducibility
  • Built-in printer
Used in testing/to measure ozone concentrations in air. It can continuously detect the ozone concentration in the outlet of the ozone generators which used on pharmaceutical, chemical, electronic, municipal, sewage treatment and other industries.

Gas Detectors

Gas Detectors : Portable 2 in 1 gas detector LPTG-A10

Portable 2 in 1 gas detector LPTG-A10

  • Sampling method
  • Diffusion
  • Sensor type
  • CO2: solid electrolyte sensor, O2:electrochemical sensor
  • Detection range
  • CO2:0.04 to 5.00 % and O2:0.0 to 30.0 %
Gas Detectors : Portable Multiple Gas Detector LPMG-A10

Portable Multiple Gas Detector LPMG-A10

  • Sampling Method
  • Diffusion
  • Working conditions
  • Temperature -20 to 50°C Pressure 0.9 to 1.1 (standard atmospheric pressure) Humidity 10 to 95 % RH (no dew condensation)
  • Explosion proof grade
  • Exia II CT3
Gas Detectors : Portable infrared gas detector LIGD-A10
Portable infrared gas detector LIGD-A10
  • Measurement principle
  • Non-dispersive infrared  (NDIR)
  • Gas Detected
  • SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.)
  • Detection Uncertainty
Gas Detectors : Portable Single Gas Detector LPSG-A10
Portable Single Gas Detector LPSG-A10
  • Sampling method
  • Diffusion
  • Measurement principle
  • Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas)
  • Detector gas
  • Flammable gases, oxygen gas, toxic and harmful gases

Digital Differential Pressure Meter

Digital Differential Pressure Meter : Digital Differential Pressure Meter LDPM-A10

Digital Differential Pressure Meter LDPM-A10

  • Measuring range
  • 0 ∼ 125 Pa
  • Accuracy
  • 0 ± 0.2 Pa (liner error) ± 1 %
  • Operating temperature range
  • 0 °C ∼ 50 °C
Digital Differential Pressure Meter : Digital Differential Pressure Meter LDPM-A20

Digital Differential Pressure Meter LDPM-A20

  • Measuring range
  • ± 500 Pa
  • Repeatability
  • ± 0.2 % FS
  • Resolution
  • 0.1 Pa

Multifunctional Environmental Meter

Multifunctional Environmental Meter : 6 in 1 Multifunctional Environmental Meter LMEM-A10

6 in 1 Multifunctional Environmental Meter LMEM-A10

  • Temperature Measurement Range
  • -10℃ to 60℃
  • Temperature Resolution
  • 0.1°C
  • Temperature Accuracy
  • ± 1.5℃
Multifunctional Environmental Meter : Floor Balance LFRB-A20

Floor Balance LFRB-A20

  • Capacity
  • 50 kg
  • Accuracy
  • 1 g
  • Speed
  • 1 s