Test Volume 100 μL
Accuracy error 0.5 %
Precision error 0.3 %
  • Autoclavable at 121 °C
  • Material: Polycarbonate
  • Excellent durability and chemical resistance
  • Ergonomic design provides excellent operating experience
  • Easy-to-read volume display
  • Trouble-free calibration and maintenance

Fixed Volume Pipettes

Fixed Volume Pipettes FVP207L

Fixed Volume Pipettes FVP207L

  • Test Volume
  • 250 μL
  • Accuracy error
  • 0.4 %
  • Precision error
  • 0.2 %
Fixed Volume Pipettes FVP209L

Fixed Volume Pipettes FVP209L

  • Test Volume
  • 1000 μL
  • Accuracy error
  • 0.3 %
  • Precision error
  • 0.2 %
Fixed Volume Pipettes FVP202L

Fixed Volume Pipettes FVP202L

  • Test Volume
  • 20 μL
  • Accuracy error
  • 0.6 %
  • Precision error
  • 0.5 %
Fixed Volume Pipettes FVP201L

Fixed Volume Pipettes FVP201L

  • Test Volume
  • 10 μL
  • Accuracy error
  • 0.8 %
  • Precision error
  • 0.8 %

Pipette Pump

Pipette Pump PPP100L

Pipette Pump PPP100L

  • Capacity
  • 2 mL
  • Color
  • Blue
  • Packaging
  • Bulk Packing
Pipette Pump PPP102L

Pipette Pump PPP102L

  • Capacity
  • 25 mL
  • Color
  • Red
  • Packaging
  • Bulk Packing
Pipette Pump PPP101L

Pipette Pump PPP101L

  • Capacity
  • 10 mL
  • Color
  • Green
  • Packaging
  • Bulk Packing

Pipette Controller

Pipette Controller PPC101L

Pipette Controller PPC101L

  • Aspiration speed
  • 25 ml < 5s
  • Dispensing speed
  • Motor/gravity
  • Aspiration/Dispensing speed
  • 8 shifts
Pipette Controller PPC100L

Pipette Controller PPC100L

  • Aspiration speed
  • 25 ml < 7s
  • Dispensing speed
  • Motor/gravity
  • Aspiration/Dispensing speed
  • NA

Fixed Volume Fully Autoclavable Pipettes

Fixed Volume Fully Autoclavable Pipettes FVP110L

Fixed Volume Fully Autoclavable Pipettes FVP110L

  • Test Volume
  • 2000 μL
  • Accuracy error
  • 0.3 %
  • Precision error
  • 0.15 %
Fixed Volume Fully Autoclavable Pipettes FVP108L

Fixed Volume Fully Autoclavable Pipettes FVP108L

  • Test Volume
  • 500 μL
  • Accuracy error
  • 0.3 %
  • Precision error
  • 0.2 %
Fixed Volume Fully Autoclavable Pipettes FVP100L

Fixed Volume Fully Autoclavable Pipettes FVP100L

  • Test Volume
  • 5 μL
  • Accuracy error
  • 1.3 %
  • Precision error
  • 1.2 %
Fixed Volume Fully Autoclavable Pipettes FVP109L

Fixed Volume Fully Autoclavable Pipettes FVP109L

  • Test Volume
  • 1000 μL
  • Accuracy error
  • 0.3 %
  • Precision error
  • 0.2 %

Single Channel Electronic pipette

Single Channel Electronic pipette SEP102L

Single Channel Electronic pipette SEP102L

  • Volume Range
  • 30 – 300 μL
  • Increment
  • 1 μL
  • Test Volume
  • 300 μL 30 μL
Single Channel Electronic pipette SEP103L

Single Channel Electronic pipette SEP103L

  • Volume Range
  • 100 - 1000 μL
  • Increment
  • 5 μL
  • Test Volume
  • 1000 μL 100 μL
Single Channel Electronic pipette SEP100L

Single Channel Electronic pipette SEP100L

  • Volume Range
  • 0.5 – 10 μL
  • Increment
  • 0.01 μL
  • Test Volume
  • 10 μL 1 μL
Single Channel Electronic pipette SEP101L

Single Channel Electronic pipette SEP101L

  • Volume Range
  • 5 – 50 μL
  • Increment
  • 0.1 μL
  • Test Volume
  • 50 μL 5 μL