Volume Range 100 - 1000 μL
Increment 5 μL
Test Volume 1000 μL <hr> 100 μL
Accuracy Error ±0.60 % <hr> ±3.00 %
Precision Error 0.20 % <hr> 0.60 %
  • Dual charging modes for longer operation time
  • Digital control and multifunctioning Pipette
  • Autoclavable (Lower part)
  • Adjustable speeds for aspiration and dispensing
  • Self-calibration, can be connected to a PC via USB for calibration
  • Accuracy Error and Precision Error is given according to ISO8655-2 standard

Single Channel Electronic pipette

Single Channel Electronic pipette SEP101L

Single Channel Electronic pipette SEP101L

  • Volume Range
  • 5 – 50 μL
  • Increment
  • 0.1 μL
  • Test Volume
  • 50 μL 5 μL
Single Channel Electronic pipette SEP100L

Single Channel Electronic pipette SEP100L

  • Volume Range
  • 0.5 – 10 μL
  • Increment
  • 0.01 μL
  • Test Volume
  • 10 μL 1 μL
Single Channel Electronic pipette SEP102L

Single Channel Electronic pipette SEP102L

  • Volume Range
  • 30 – 300 μL
  • Increment
  • 1 μL
  • Test Volume
  • 300 μL 30 μL

Pipette Pump

Pipette Pump PPP100L

Pipette Pump PPP100L

  • Capacity
  • 2 mL
  • Color
  • Blue
  • Packaging
  • Bulk Packing
Pipette Pump PPP101L

Pipette Pump PPP101L

  • Capacity
  • 10 mL
  • Color
  • Green
  • Packaging
  • Bulk Packing
Pipette Pump PPP102L

Pipette Pump PPP102L

  • Capacity
  • 25 mL
  • Color
  • Red
  • Packaging
  • Bulk Packing

Pipette Controller

Pipette Controller PPC100L

Pipette Controller PPC100L

  • Aspiration speed
  • 25 ml < 7s
  • Dispensing speed
  • Motor/gravity
  • Aspiration/Dispensing speed
  • NA
Pipette Controller PPC101L

Pipette Controller PPC101L

  • Aspiration speed
  • 25 ml < 5s
  • Dispensing speed
  • Motor/gravity
  • Aspiration/Dispensing speed
  • 8 shifts

Fixed Volume Fully Autoclavable Pipettes

Fixed Volume Fully Autoclavable Pipettes FVP102L

Fixed Volume Fully Autoclavable Pipettes FVP102L

  • Test Volume
  • 20 μL
  • Accuracy error
  • 0.6 %
  • Precision error
  • 0.5 %
Fixed Volume Fully Autoclavable Pipettes FVP111L

Fixed Volume Fully Autoclavable Pipettes FVP111L

  • Test Volume
  • 5000 μL
  • Accuracy error
  • 0.3 %
  • Precision error
  • 0.15 %
Fixed Volume Fully Autoclavable Pipettes FVP105L

Fixed Volume Fully Autoclavable Pipettes FVP105L

  • Test Volume
  • 100 μL
  • Accuracy error
  • 0.5 %
  • Precision error
  • 0.3 %
Fixed Volume Fully Autoclavable Pipettes FVP101L

Fixed Volume Fully Autoclavable Pipettes FVP101L

  • Test Volume
  • 10 μL
  • Accuracy error
  • 0.8 %
  • Precision error
  • 0.8 %

Fixed Volume Pipettes

Fixed Volume Pipettes FVP204L

Fixed Volume Pipettes FVP204L

  • Test Volume
  • 50 μL
  • Accuracy error
  • 0.5 %
  • Precision error
  • 0.3 %
Fixed Volume Pipettes FVP200L

Fixed Volume Pipettes FVP200L

  • Test Volume
  • 5 μL
  • Accuracy error
  • 1.3 %
  • Precision error
  • 1.2 %
Fixed Volume Pipettes FVP202L

Fixed Volume Pipettes FVP202L

  • Test Volume
  • 20 μL
  • Accuracy error
  • 0.6 %
  • Precision error
  • 0.5 %
Fixed Volume Pipettes FVP208L

Fixed Volume Pipettes FVP208L

  • Test Volume
  • 500 μL
  • Accuracy error
  • 0.3 %
  • Precision error
  • 0.2 %