Volume Range 10 - 100 μL
Increment 1 μL
Test Volume 100 μL <hr> 50 μL <hr> 10 μL
Accuracy error 0.80 % <hr> 1.00 % <hr> 3.00 %
Precision error 0.15 % <hr> 0.40 % <hr> 1.50 %
  • Autoclavable at 121 °C
  • Material: Polycarbonate
  • Available in 0.1 µL to 10000 µL volume
  • Ergonomic design provides excellent operating experience
  • Easy-to-read volume display
  • Trouble-free calibration and maintenance

Variable Volume Pipette

Variable Volume Pipette VVP203L

Variable Volume Pipette VVP203L

  • Volume Range
  • 5 - 50 μL
  • Increment
  • 0.5 μL
  • Test Volume
  • 50 μL 25 μL 5 μL
Variable Volume Pipette VVP201L

Variable Volume Pipette VVP201L

  • Volume Range
  • 0.5 - 10 μL
  • Increment
  • 0.1 μL
  • Test Volume
  • 10 μL 5 μL 1 μL
Variable Volume Pipette VVP207L

Variable Volume Pipette VVP207L

  • Volume Range
  • 100 - 1000μL
  • Increment
  • 5 μL
  • Test Volume
  • 1000 μL 500 μL 100 μL
Variable Volume Pipette VVP205L

Variable Volume Pipette VVP205L

  • Volume Range
  • 20 - 200 μL
  • Increment
  • 1 μL
  • Test Volume
  • 200 μL 100 μL 20 μL

Pipette Pump

Pipette Pump PPP101L

Pipette Pump PPP101L

  • Capacity
  • 10 mL
  • Color
  • Green
  • Packaging
  • Bulk Packing
Pipette Pump PPP102L

Pipette Pump PPP102L

  • Capacity
  • 25 mL
  • Color
  • Red
  • Packaging
  • Bulk Packing
Pipette Pump PPP100L

Pipette Pump PPP100L

  • Capacity
  • 2 mL
  • Color
  • Blue
  • Packaging
  • Bulk Packing

Pipette Controller

Pipette Controller PPC101L

Pipette Controller PPC101L

  • Aspiration speed
  • 25 ml < 5s
  • Dispensing speed
  • Motor/gravity
  • Aspiration/Dispensing speed
  • 8 shifts
Pipette Controller PPC100L

Pipette Controller PPC100L

  • Aspiration speed
  • 25 ml < 7s
  • Dispensing speed
  • Motor/gravity
  • Aspiration/Dispensing speed
  • NA

Fixed Volume Fully Autoclavable Pipettes

Fixed Volume Fully Autoclavable Pipettes FVP100L

Fixed Volume Fully Autoclavable Pipettes FVP100L

  • Test Volume
  • 5 μL
  • Accuracy error
  • 1.3 %
  • Precision error
  • 1.2 %
Fixed Volume Fully Autoclavable Pipettes FVP101L

Fixed Volume Fully Autoclavable Pipettes FVP101L

  • Test Volume
  • 10 μL
  • Accuracy error
  • 0.8 %
  • Precision error
  • 0.8 %
Fixed Volume Fully Autoclavable Pipettes FVP102L

Fixed Volume Fully Autoclavable Pipettes FVP102L

  • Test Volume
  • 20 μL
  • Accuracy error
  • 0.6 %
  • Precision error
  • 0.5 %
Fixed Volume Fully Autoclavable Pipettes FVP105L

Fixed Volume Fully Autoclavable Pipettes FVP105L

  • Test Volume
  • 100 μL
  • Accuracy error
  • 0.5 %
  • Precision error
  • 0.3 %

Fixed Volume Pipettes

Fixed Volume Pipettes FVP210L

Fixed Volume Pipettes FVP210L

  • Test Volume
  • 2000 μL
  • Accuracy error
  • 0.3 %
  • Precision error
  • 0.15 %
Fixed Volume Pipettes FVP200L

Fixed Volume Pipettes FVP200L

  • Test Volume
  • 5 μL
  • Accuracy error
  • 1.3 %
  • Precision error
  • 1.2 %
Fixed Volume Pipettes FVP209L

Fixed Volume Pipettes FVP209L

  • Test Volume
  • 1000 μL
  • Accuracy error
  • 0.3 %
  • Precision error
  • 0.2 %
Fixed Volume Pipettes FVP207L

Fixed Volume Pipettes FVP207L

  • Test Volume
  • 250 μL
  • Accuracy error
  • 0.4 %
  • Precision error
  • 0.2 %