Specific Gravity Tester LSGT-A10 determines the theoretical maximum specific gravity of bituminous mixtures in accordance to ASTM D2041 Standard Test Method for Theoretical Maximum Specific Gravity of Bituminous Mixtures (Vacuum process). Adopted with single chip machine technology to shake a loose asphalt mixture sample submerged in water. Vacuum is applied into the sample, to extract out the air bubble.

Vessel Volume  4000 ml × 2
Power of Vacuum pump 160 W
Negative power 3.7 kPa(27.75 mmHg)
Power of shaking machine 30 W
Power supply AC(220±10%)V, 50Hz
Dimension 510×520×380 mm
  • High test efficiency
  • Test 2 samples at one time
  • Adopts single chip machine technology
  • Equipped with a high-accuracy absolute pressure sensor
  • Vacuum meter showing working status of vacuum pump
  • Water buffer device preventing water flow from negative pressure container into the vacuum pump
Suitable for measuring theoretical specific gravity of bituminous mixtures. Can also be used for the calculation of the percent of air voids in compacted bituminous mixtures and the amount of bitumen absorbed by the aggregates.

Specific Gravity Tester

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml
Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml
Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg

Octane Number & Cetane Number Tester

Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON
Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max

Acid and Alkali Tester

Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml
Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL
Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml
Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV

Aniline Test Equipment

Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W
Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V