Labtron Viscometer LVM-A10 is especially designed with spindles for measuring shear rate and shear stress. In addition to providing accurate shear rate and shear stress, they are configured with Resistance Temperature Detector (RTD) and stepper motor for accurate and reliable operation.

Measuring range 1 - 6,000,000 cP, 100 - 40,000,000 cP, 200 - 80,000,000 cP, 800 - 320,000,000 cP
Rotating speed 0.1 - 200 rpm
Measuring Error (Newtonian liquid) ± 1.0 % full range
Repeatability error (Newtonian liquid)) ± 0.5 %
Power 100 / 240 V
  • Compact, reliable and powerful and user friendly software
  • Efficiently shows the largest viscosity and continuous change in viscosity
  • Bi-directional interface: RS-232PC or 485
  • Alarm alerts if the measurement is out of range
  • Linear correction with excellent in interference immunity
Our product Viscometer has its use in quality control applications to give precise and accurate results of viscosity measurement, also it is used to study flow behavior of liquid and semi solid materials like pharmaceuticals, juices, dairy products, organic solvent, ink, glue, polymer solutions, cosmetics, etc.

Rotational Viscometers

Viscometer LVM-A21

Viscometer LVM-A21

  • Viscosity Range
  • RV: 100 to 13000000 mPa.s
  • Rotation speed range
  • 0.3 to 100 rpm (stepless)
  • Spindles
  • RV: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Viscometer LVM-D10

Viscometer LVM-D10

  • Measurement range
  • 25 mPa.s to 1×10000000 mPa.s
  • Rotors
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
  • Rotor speed
  • (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min
Viscometer LVM-A41

Viscometer LVM-A41

  • Rotational speed range
  • 0.3 to 100 rpm
  • Standard Rotor
  • Rotor R2 to R7 (6, Standard), R1 (Apolegamy)
  • Viscosity measurement range
  • Rotor R2 to R7:100 to 4000 M (mPa.s)
Viscometer LVM-A40

Viscometer LVM-A40

  • Viscosity Range
  • 3 to 1600000 M (mPa.s)
  • Rotation speed range
  • 0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100 Total 18 rpm
  • Spindles
  • 18# rotor:3 to 10 K; 7 ml 25# rotor:480 to 1.6 M; 9 ml 31# rotor:30 to 100 K; 10.5 ml 34# rotor:60 to 200 K; 11 ml

Ubbelohde Viscometer

Ubbelohde Viscometer LUV-A11

Ubbelohde Viscometer LUV-A11

  • Measuring range
  • 0.3 - 50000 mm2/s
  • Measure position
  • 4
  • Bath volume
  • 33 L
Automatic Ubbelohde viscometer LUV-B10

Automatic Ubbelohde viscometer LUV-B10

  • Measuring range
  • 0.35 to 5000 mm2/s
  • Measure position
  • 2 (4 units measuring position at option)
  • Bath volume
  • 12 L
Ubbelohde Viscometer LUV-A10

Ubbelohde Viscometer LUV-A10

  • Measuring range
  • 0.3 - 50000 mm2/s
  • Measure position
  • 2
  • Bath volume
  • 25 L
Ubbelohde Viscometer LUV-A12

Ubbelohde Viscometer LUV-A12

  • Measuring range
  • 0.3 - 50000 mm2/s
  • Measure position
  • 6
  • Bath volume
  • 41 L

Cone Viscometers

Cone Plate Viscometer LCPV-A10

Cone Plate Viscometer LCPV-A10

  • Accuracy
  • ± 2 % (F.S)
  • Temperature
  • -1℃ to 150℃ (± 0.1℃)
  • Spindle Details
  • Spindle No CAP-01 CAP-04 Shear Rate 13.3 N 3.3 N Sample Volume 67µL 134µL LCPV-A10 (400rpm) 47-469 300-3,750 LCPV-A10 (750rpm) 25-250 200-2,000 LCPV-A10 (900rpm) 20-208 170-1,667