Vacuum Distillation Tester LDT-A13 is designed to determine distillation properties of products like paraffin oil, lubricating oil and other high boiling point petroleum products. Composed of distillation & vacuum parts, it is complied with ASTM D1160 standard Test Method for (Distillation of Petroleum Products at Reduced Pressure).

Ambient temperature 5 °C to 35 ℃
Relative humidity ≤ 85 %
Cubage of buffer vessel 1000 ml
Max. Residual pressure ≤ 2 mm Hg
Temperature controlling accuracy ± 1 ℃
Temperature range air bath Ambient temperature ~ 100 ℃ adjustable
Heating power for distillation flask 1000 W
Heating power for receiving flask 350 W
Power supply AC 220 V, 50 Hz
  • Continuous adjustment for heating power of furnace
  • High quality cooling device to cool down temperature of the heating furnace
  • Excellent vacuum performance, with maximum reduced pressure 2 mmHg
  • Air bath with Pt 100 temperature sensor
  • Air bath with Digital temperature controller
Used to determine high boiling point petroleum products, such as paraffin oil, lubricating oil, and others at reduced pressure.

Distillation Tester

Benzene Distillation Tester (Low Temperature) LDT-A11

Benzene Distillation Tester (Low Temperature) LDT-A11

  • Ambient temperature
  • -10°C to 35°C
  • Relative humidity
  • ≤ 85 %
  • Thermometer
  • Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Distillation Tester (low temperature single unit) LDT-A17

Distillation Tester (low temperature single unit) LDT-A17

  • Graduated flasks
  • 100 ml
  • Distillation flask
  • 125 mL
  • Ambient temperature
  • ≤ 30 °C
Distillation Tester (low temperature Double units) LDT-A16

Distillation Tester (low temperature Double units) LDT-A16

  • Graduated flasks
  • 100 ml
  • Distillation flask
  • 125 ml
  • Ambient temperature
  • ≤ 35 °C
Distillation Tester Front Type LDT-A14

Distillation Tester Front Type LDT-A14

  • Distillation flask
  • 125 mL
  • Ambient temperature
  • Room temperature to 35 °C
  • Relative humidity
  • ≤ 85 %

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml
Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml

Octane Number & Cetane Number Tester

Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max
Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON

Acid and Alkali Tester

Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml
Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL
Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml
Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV

Aniline Test Equipment

Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W
Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V