Atomic Fluorescence Spectrometer LAFS-A10 is a microprocessor controlled double-channel, non-dispersive unit used for trace element composition, ultra-trace analysis of Mercury and all other hydride-forming elements. Pre adjusted referral optical plane to coincide atomizer center with optical focus. Equipped with a feature of real time conversion of data into graph.

Beam Configuration Dual Channel
Elements ( Measuring Range ) <table class='table table-striped table-bordered table-responsive'><tr><td><strong>As, Se, Pb, Bi, Sb, Te, Sn</strong></td><td>< 0.01 µg/L</td></tr><tr><td><strong>Hg, Cd</strong></td><td>< 0.001 µg/L</td></tr><tr><td><strong>Zn</strong></td><td>< 1.0 µg/L</td></tr><tr><td><strong>Ge</strong></td><td>< 0.1 µg/L</td></tr></table>
Precision ( RSD ) < 1.0
Linear range More than 3 orders of magnitude
Lamp Hollow cathode lamp
Power Supply 220 V
Dimension 1000 x 350 x 390 mm
Weight 70 Kg
  • Double channel detection for trace element analysis
  • Peak height and peak area integral detection method
  • High stability light source
  • High intensity hollow cathode lamps for high sensitivity and stability
  • Gas - liquid separator for improved repeatability of results
  • Double shielded quartz atomizer with automatic igniting argon – hydrogen flame
  • Stable gas flow
  • Automatic gas alarm pressure at critical point
  • USB communication for real time automatic detection
Used in analysis / detection of compound present in air of water, heavy metal detection, redirect photons , in various fields of geology, metallurgy, medicine, chemical industry, food inspection, water supply, waste water treatment and scientific research.

Atomic Fluorescence Spectrometer

FTIR Spectrometer

FTIR Spectrometer LIR-B10

FTIR Spectrometer LIR-B10

  • Spectral Range
  • 7800 cm-1 to 350 cm-1
  • Resolution
  • 0.85 cm-1
  • Wave number precision
  • ± 0.01 cm-1

ICP Spectrometer

ICP spectrometer LICP-A10

ICP spectrometer LICP-A10

  • Wavelength range ( 3600 lines / mm )
  • 180 to 500 nm
  • Wavelength range ( 2400 lines / mm )
  • 180 to 800 nm
  • Temperature
  • 20 ~ 28 °C
ICP Spectrometer LICP-B10

ICP Spectrometer LICP-B10

  • Monochromator Specifications
  • Optical typeCzerny turnerResolution≤ 0.015nm (3600 line grating) ≤ 0.030nm (2400 line grating)Focal length1000 mmGrating specificationshuge holographic grating with 3600 L/mil or 2400 L/mil and 80 mm × 100 mm of ruling areaWavelength range195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating
  • Solid State Power Specifications
  • Frequency27.12 MHz Frequency stability: < 0.05%Spray chamberScott double pass spray chamberOutput power800 W to 1600 W, adjustable with power efficiency more than 65%Output power stability≤ 0.05%Induction coil25 mm × 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)
  • Technical Specifications
  • Suitable sample content rangeLiquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%Repeatabilityshort-term stability- RSD ≤ 1.5% Long-term stability: RSD ≤ 2%Test speed5 to 8 elements / minLimits of detection (LOD, µg/L) for most elements1ppb to 10ppb
ICP Spectrometer LICP-A11

ICP Spectrometer LICP-A11

  • Wavelength range
  • 180 to 900 nm
  • Elements per minute
  • 15 elements
  • Temperature
  • 29 °C

XRF Spectrometer

Handheld XRF Spectrometer LXRF-B11

Handheld XRF Spectrometer LXRF-B11

  • Analytical Method
  • Energy dispersive X-ray fluorescence analytical Method
  • Elements Measuring
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
  • Range
  • Simultaneous detector
Handheld XRF Spectrometer LXRF-B10

Handheld XRF Spectrometer LXRF-B10

  • Analytical Method
  • Energy dispersive X-ray fluorescence analytical Method
  • Elements Measuring
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
  • Range
  • Simultaneous detector
XRF-Spectrometer LXRF-A10

XRF-Spectrometer LXRF-A10

  • Measureable elements
  • S to U
  • Detection limit
  • 1 ppm
  • Temperature
  • 15 ~ 30 °C

XRD Diffractometer

XRD Diffractometer LXRD-A10

XRD Diffractometer LXRD-A10

  • X-ray Tuble
  • Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kW
  • Focus Size
  • 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm
  • Stability
  • ≤ 0.01 %