Multi parameter water quality analyzer LMWA-A10
- COD: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>COD determination range</strong></td><td>2 to 10000 mg/ L</td></tr><tr><td><strong>COD measurement accuracy</strong></td><td>COD < 50 mg/ L, ≤ ± 10 %
and
COD > 50 mg/ L, ≤ ± 5 %</td></tr><tr><td><strong>COD minimum detection limit</strong></td><td>0.1 mg/ L</td></tr><tr><td><strong>COD measurement time</strong></td><td>20 minutes</td></tr><tr><td><strong>COD repeatability</strong></td><td>≤ ± 5 %</td></tr><tr><td><strong>Consumables for colorimetric COD measurement</strong></td><td>Colorimetric tubes and Cuvette</td></tr><tr><td><strong>COD reactor digestion temperature</strong></td><td>165 ± 0.5°C</td></tr><tr><td><strong>COD reactor digestion time</strong></td><td>10 min</td></tr><tr><td><strong>COD reactor time setting switches</strong></td><td>3 pcs</td></tr><tr><td><strong>Anti-chlorine interference</strong></td><td>(Cl) < 1000 mg/ L No effect</td></tr></table>
- Ammonia nitrogen: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Ammonia nitrogen determination range</strong></td><td>0.02 to 60 mg/ L</td></tr><tr><td><strong>Ammonia nitrogen measurement accuracy</strong></td><td>≤ ± 10 %</td></tr><tr><td><strong>Ammonia nitrogen minimum detection limit</strong></td><td>0.01 mg/ L</td></tr><tr><td><strong>Ammonia nitrogen measurement time</strong></td><td>10 to 15 minutes</td></tr><tr><td><strong>Ammonia nitrogen repeatability</strong></td><td>≤ ± 5 %</td></tr><tr><td><strong>Consumables for colorimetric ammonia nitrogen measurement</strong></td><td>Colorimetric tubes and Cuvette</td></tr><tr><td><strong>Ammonia nitrogen reactor time setting switches</strong></td><td>3 pcs</td></tr></table>
- Total phosphorous: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Total phosphorous determination range</strong></td><td>0.002 to 20 mg/ L</td></tr><tr><td><strong>Total phosphorous total phosphorous measurement accuracy</strong></td><td>≤ ± 5 %</td></tr><tr><td><strong>Total phosphorous minimum detection limit</strong></td><td>0.001 mg/ L</td></tr><tr><td><strong>Total phosphorous measurement time</strong></td><td>35 to 50 minutes</td></tr><tr><td><strong>Total phosphorous repeatability</strong></td><td>≤ ± 5 %</td></tr><tr><td><strong>Consumables for colorimetric total phosphorous measurement</strong></td><td>Colorimetric tubes and Cuvette</td></tr><tr><td><strong>Total phosphorous reactor digestion temperature</strong></td><td>120 ± 0.5°C</td></tr><tr><td><strong>Total phosphorous reactor digestion time</strong></td><td>30 min</td></tr><tr><td><strong>Total phosphorous reactor time setting switches</strong></td><td>3 pcs</td></tr></table>
- Turbidity: <table class='table table-striped table-bordered table-responsive'><tr><td><strong>Turbidity determination range</strong></td><td>0.5 to 400 NTU</td></tr><tr><td><strong>Turbidity measurement accuracy</strong></td><td>≤ ± 5 %</td></tr><tr><td><strong>Turbidity minimum detection limit</strong></td><td>0.1 NTU</td></tr><tr><td><strong>Turbidity measurement time</strong></td><td>1 minute</td></tr><tr><td><strong>Turbidity repeatability</strong></td><td>≤ ± 5 %</td></tr><tr><td><strong>Consumables for colorimetric turbidity measurement</strong></td><td>Colorimetric Cuvette</td></tr></table>