Differential Scanning Calorimeter LDSC-A12

Differential Scanning Calorimeter LDSC-A12


Differential Scanning Calorimeter LDSC-A12 is a compact and tabletop type fully automatic controlled unit. Features -150 to 550°C of temperature range with 0.1 to 80°C/min of heating rate and 1 to 20°C/min of cooling rate. Designed with metal furnace body and 7-inch touch screen display, has liquid nitrogen refrigeration cooling and 3 sets of thermocouples for efficient operation. Adopted with indirect conduction method for heating and automatic switching of 2-channel atmosphere flow, comes with software control and USB interface for convenient operation and easy data analysis.





Temperature range-150°C to 550°C
Temperature resolution0.001°C
Temperature fluctuations± 0.001°C
Temperature repeatability± 0.1°C
Constant temperature rangeProgram setting ≤ 24 hr
Dynamic heat flow range (DSC range)0 to ± 600 mW
Heating rate0.1 to 80°C / min
Cooling rate1 to 20°C / min (For instant cool only, cannot be Isothermal below RT, and if heating up, the rate can be controlled)
DSC noise0.01 μW
DSC resolution0.01 µW
DSC accuracy0.01 µW
Control ModeRising temperature, constant temperature (full-automatic)
Curve scanningRising scan, cooling scan
Gas flow controlEmbedded digital flow meter and Software control, automatic changing
Atmosphere control gasNitrogen, Oxygen (auto-switch)
Gas flow-rate0 to 300 ml/min
Gas pressure0.2 MPa
Cooling deviceLiquid nitrogen refrigeration
Thermocouples3 sets
Parameter standardWith standard material, with calibration function, the user may correct temperature and heat enthalpy
Display7 inches LCD touch screen display
Data interfaceStandard USB connector
Power supplyAC 220 V/50 Hz
Dimension (W×D×H)680×620×550 mm
Weight38 kg
  • A compact and tabletop type fully automatic controlled unit
  • -150 to 550°C of temperature range with 0.001°C resolution
  • 0.1 to 80°C/min of heating rate and 1 to 20°C/min of cooling rate
  • Metal furnace body with 7-inch touch screen display
  • Liquid nitrogen refrigeration cooling and 3 sets of thermocouples
  • Indirect conduction method for heating, high stability and uniformity
  • Automatic switching of 2-channel atmosphere flow, short stabilization time
  • Software control and USB interface, easy and convenient data analysis
  • Ideal to determine the inner heat transition relating to temperature and heat flow
Differential Scanning Calorimeter is used for the identification of various physical properties and thermal transitions of polymeric materials across polymer development, performance testing & quality control etc.
Aluminum crucibles × 100 pcs
Ceramic crucibles × 100 pcs
Pure tin grains × 1 bag